ManTag 200 / 200E — Help

Version V1 · SDS200 / SDS200E browser interface · © 2026 mantag.eu · Powered by e-report CORE

1. What ManTag does

ManTag automatically monitors supported Uniden SDS200 / SDS200E scanner activity, creates a searchable event log and records received calls. Logged data can include frequency, channel, system, mode, CTCSS/DCS, DMR metadata, signal level, RSSI and call duration when the scanner provides those values.

Recordings can be replayed directly from the LOG, copied to Dropbox, downloaded as WAV and LOG channel data can be exported in a tab-delimited TXT format prepared for Uniden Sentinel.

2. Download and start ManTag V1

Download ManTag 200 V1 Trial and extract the complete ZIP folder before starting ManTag.

Double-click START.bat. ManTag uses scanner IP 192.168.50.2 automatically after a 5-second countdown. Press I during the countdown only if you need to enter a different scanner IP.

START.bat starts the local LAN bridge and Dropbox sync service, then opens index.html automatically in your default browser.

Use a current version of Google Chrome or Microsoft Edge. Keep the ManTag folder and its small background services running while ManTag is in use. Start only one ManTag instance at a time.

Browser tips: F11 = full screen · F11 again = normal window · Ctrl+0 = browser zoom 100%.

3. Trial and licensing

The downloadable ManTag 200 V1 package is the full application with a 20 committed LOG-call trial limit per scanner ESN. Clearing the LOG or deleting rows does not reset the trial counter.

ManTag reads the connected SDS200 / SDS200E scanner ESN automatically. A paid license is linked to the scanner, not to one Windows PC. The current public license is Annual only — US$14.90/year. Purchase is available through the secure Polar checkout on mantag.eu.

When the trial limit is reached, use the LICENSE control in ManTag to enter the activation key after purchase.

4. USB scanner data

Connect the SDS200 / SDS200E to the PC by USB. When the scanner asks for the USB mode, select Serial Port — do not select Mass Storage / SD mode. Then click CONNECT USB in ManTag.

ManTag uses the scanner serial data connection for call metadata, scanner status and Waterfall information. Use DISCONNECT USB before unplugging or changing the USB connection.

USB carries scanner data only. Audio recording is handled separately by LAN or LINE IN.

5. LAN audio — SDS200 / SDS200E

For the best SDS200 / SDS200E recording quality, use LAN audio. Configure the PC and scanner as shown below, then connect using CONNECT LAN in ManTag.

A. Windows PC — Ethernet settings

SettingValue
IPv4 address192.168.50.1
Subnet mask255.255.255.0
Default gatewayLeave blank on the PC for a direct scanner connection
DNSLeave blank

Where to set it in Windows 10 / 11:
Settings → Network & Internet → Ethernet → IP assignment → Edit → Manual → enable IPv4.

Enter 192.168.50.1 as the PC Ethernet IPv4 address and 255.255.255.0 as the subnet mask. For a direct scanner-to-PC Ethernet connection, the PC gateway and DNS can remain empty. The scanner Default Gateway is set separately to 192.168.50.1.

B. Uniden SDS200 / SDS200E — LAN settings

Scanner menu path:
MENU → SETTINGS → LAN SETTINGS → SET IP ASSIGNMENTS → MANUAL

Select MANUAL, then open Set IP Addresses and enter all network values exactly as shown below:

Scanner menu itemValue
Set IP Address192.168.50.2
Set Subnet Mask255.255.255.0
Set Default Gateway192.168.50.1
Set DNS ServerLeave unchanged / not required for the direct ManTag connection
Scanner setup summary:
IP Address = 192.168.50.2
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.50.1

START.bat uses 192.168.50.2 by default. Press I during its 5-second countdown to use another scanner IP. The Windows PC Ethernet adapter uses 192.168.50.1, so both devices are on the same 192.168.50.x network.

C. ManTag — LAN audio connection

SettingValue
RTSP port554
RTSP path/au:scanner.au
Local ManTag Bridge127.0.0.1:8765

After the PC and scanner network settings are configured, start ManTag and click CONNECT LAN.

Quick check: PC = 192.168.50.1 · Scanner = 192.168.50.2 · Subnet Mask = 255.255.255.0 · Scanner Default Gateway = 192.168.50.1.

6. LINE IN audio

Click CONNECT LINE IN to use an audio input connected to the PC. Select the correct Windows input device when the browser asks for permission.

For clean recordings, avoid excessive scanner volume. LINE IN recordings are stored in the browser-supported audio format and can be exported as WAV through the AUDIO download control.

7. Live monitor and Waterfall

The upper live panel shows the current scanner activity. Waterfall data appears when Waterfall is enabled on the SDS200-E. Waterfall HOLD activity can also create LOG entries and recordings.

Some metadata may be unavailable in specific scanner modes. A dash means the scanner did not provide a usable value.

8. LOG and filtering

Each completed call becomes one LOG row. ManTag keeps and displays up to the latest 1000 LOG records. This limit applies to the local ManTag LOG; Dropbox recording storage is not limited to 1000 records and is controlled by the selected Dropbox retention setting.

Use FILTER LOG to search frequency, channel, system, TGID, UID and other displayed metadata.

ALL / UNPLAYED / PLAYED filters recordings by playback state. TIME ↑ / TIME ↓ changes chronology. CLEAR LOG clears the complete LOG after confirmation.

9. Playback controls

ControlFunction
AUTO PLAYPlays all currently displayed recordings from top to bottom.
SPEED0.5×, 0.75×, 1×, 1.25× or 1.5×.
PREV / NEXTMoves within the current filtered and sorted playback order.
PAUSE / RESUMEPauses or resumes the current recording without changing position.
STOPStops playback and AUTO PLAY.

The active row is highlighted with blue text without changing row size.

10. AUDIO column

Each LOG row uses compact AUDIO controls:

IconFunction
▶ / ■One toggle button. ▶ starts this recording and changes to ■ while it is playing. ■ stops playback. After playback ends, the button returns to ▶.
↓Download this recording as WAV. Existing WAV files are downloaded directly; other supported formats are converted first.
×Delete only this LOG row. If the row owns a recording, the matching local audio file is deleted as well.

If a recording is missing, unavailable AUDIO functions remain blank.

11. Dropbox / Audio storage

Click DROPBOX / AUDIO to configure Dropbox synchronization, local recording retention and minimum call length.

Both Dropbox and local recordings support: 12 HOURS (default) · 24 HOURS · 3 DAYS · 7 DAYS · 14 DAYS · KEEP ALL.

The default retention is 12 HOURS for both Local recordings and Dropbox. Retention deletes recordings older than the selected period.

Dropbox itself is not limited to 1000 records. Its content is controlled by the selected Dropbox retention period. When a synchronized Dropbox file is deleted locally, Dropbox may synchronize that deletion to the cloud.

12. Sentinel TXT export

SENTINEL exports the currently displayed LOG result as a tab-delimited TXT file prepared for copy/paste into Uniden Sentinel. The export follows the active LOG filter and time order and contains data rows only — no header row.

Audio is not embedded in the Sentinel export.

13. DAY / NIGHT

Use the DAY / NIGHT menu control to switch the interface theme. The selected theme is stored locally in the browser and restored the next time ManTag is opened.

14. Troubleshooting

ProblemCheck
USB does not connectUSB cable, Windows COM connection, scanner USB mode and whether another program is using the scanner port.
LAN LED is offScanner IP, same local network, Bridge running, RTSP availability.
No recordingCorrect active audio source: LAN for SDS200-E or selected LINE IN device.
Waterfall is emptyEnable Waterfall on the SDS200-E and keep USB data connected.
Metadata shows “—”The scanner may not provide that field in the current receiving mode.
Dropbox does not updateDropbox Desktop running, path valid and synchronization available.

15. Files and privacy

ManTag stores LOG/configuration data locally and recordings in its recordings storage. Dropbox synchronization is optional. Scanner monitoring data is processed locally by the ManTag background components and browser interface.

16. About

ManTag 200 / SDS200E
Version V1
Modular SDS200 logger

© 2026 mantag.eu · Powered by e-report CORE